Osteointegrazione precoce con impianti personalizzati in idrossiapatite nella ricostruzione cranica in un unico passaggio
Scopri l'articolo che illustra l'osteointegrazione precoce con impianti personalizzati in idrossiapatite
📊 Study Design
- Type: Prospective, single-centre study
- Patients: 14 patients (13 adults, 1 paediatric)
- Clinical Setting: Tumor-related cranial bone resection followed by one-step reconstruction
- Material: Custom-made hydroxyapatite cranial implants
- Follow-Up Assessments: 6 weeks and 3 months
- Patient-Reported Outcomes: FACE-Q satisfaction questionnaire
🔍 Key Findings
- Mean implant-edge osteointegration reached 72.2% at 6 weeks
- Osteointegration increased to 82.6% at 3 months
- Patients reported high satisfaction scores following reconstruction
- The one-step surgical approach was reported as safe and effective, particularly in the management of large cranial bone defects
🧩 Clinical Perspective
Custom-made HA implants may represent a reconstructive option when:
- Large cranial defects require anatomical precision
- Immediate reconstruction following tumor resection is planned
- Long-term biological integration is considered relevant for clinical outcomes
- Patient-reported outcomes are included in treatment evaluation
condividi
: